High Power Test of X-band Single Cell HOM-free Choke-mode Damped Accelerating Structure Made by Tsinghua University
Xiaowei Wu,Jiaru Shi,Huaibi Chen,Walter Wuensch,T. Higo,T. Abe,Hao Zha
DOI: https://doi.org/10.18429/jacow-ipac2016-thpor043
2016-01-01
Abstract:As an alternative design for CLIC main accelerating structures, X-band choke-mode damped structures had been studied for several years. However, the performance of choke-mode cavity under high power is still in lack of research. Two standing wave single cell choke-mode damped accelerating structures with different choke dimensions which are working at 11.424 GHz were designed, manufactured and bench tested by accelerator group in Tsinghua University. High power test was carried out on it to study the breakdown phenomenon in high gradient. A single cell structure without choke which almost has the same inner dimension as choke-mode cavity will also be tested to make a comparison and study how the choke affects high-gradient properties. 7th International Particle Accelerator Conference, Busan, Korea, 8 13 May 2016 Geneva, Switzerland 12 May 2016 CLIC – Note – 1105 HIGH POWER TEST OF X-BAND SINGLE CELL HOM-FREE CHOKEMODE DAMPED ACCELERATING STRUCTURE MADE BY TSINGHUA UNIVERSITY Xiaowei Wu*1,2, Jiaru Shi†1,2, Hao Zha1,2,3, Huaibi Chen1,2, Toshiyasu Higo3, Tetsuo Abe3, Walter Wuensch4, 1Department of Engineer Physics, Tsinghua University, Beijing 100084, China 2Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Beijing 100084, China 3KEK, Tsukuba, 305-0801, Japan 4CERN, Geneva, Switzerland Abstract As an alternative design for CLIC main accelerating structures, X-band choke-mode damped structures had been studied for several years. However, the performance of choke-mode cavity under high power is still in lack of research. Two standing wave single cell choke-mode damped accelerating structures with different choke dimensions which worked at 11.424 GHz were designed, manufactured and bench tested by accelerator group in Tsinghua University. High power test has started on it to study the breakdown phenomenon in high gradient. A single cell structure without choke which almost has the same inner dimension as choke-mode cavity will also be tested to make a comparison and study how the choke affects high-gradient properties.As an alternative design for CLIC main accelerating structures, X-band choke-mode damped structures had been studied for several years. However, the performance of choke-mode cavity under high power is still in lack of research. Two standing wave single cell choke-mode damped accelerating structures with different choke dimensions which worked at 11.424 GHz were designed, manufactured and bench tested by accelerator group in Tsinghua University. High power test has started on it to study the breakdown phenomenon in high gradient. A single cell structure without choke which almost has the same inner dimension as choke-mode cavity will also be tested to make a comparison and study how the choke affects high-gradient properties.