Design of the 7mev Linac Injector for the 200mev Synchrotron of the Xi'an Proton Application Facility
Qingzi Xing,Cheng,Changtong Du,Lei Du,Taibin Du,Weiqiang Guan,Xialing Guan,Yu He,Hongping Jiang,Jian Li,Chuanxiang Tang,Ruo Tang,Baichuan Wang,Dan Wang,Xuewu Wang,Zhongming Wang,Lin Wu,Wenlong Yang,Ye Yang,Zhang Huayi,Qingzhu Zhang,Chen Zhao,Shu-xin Zheng
DOI: https://doi.org/10.18429/jacow-ipac2016-mopmw014
2016-01-01
Abstract:We present, in this paper, the design result of the 7 MeV linac which will inject the negative hydrogen ion beam to the downsteam synchrotron of the Xi`an Proton Application Facility (XiPAF). This newly designed facility will be located in Xi’an city and provide the proton beam with the maximum energy of 230 MeV for the research of the single event effect. The 7 MeV linac injector is composed of the 50 keV negative hydrogen ion source, Low Energy Beam Transport line (LEBT), 3 MeV four-vane type Radio Frequency Quadrupole (RFQ) accelerator, 7 MeV Alvarez-type Drift Tube Linac (DTL), and the corresponding RF power source system. The output beam of the linac injector is designed with the peak current of 5 mA, maximum repetition frequency of 0.5 Hz, beam pulse width of 10~40 s and RMS normalized emittance of 0.24 mm•mard. INTRODUCTION To fulfill the need of the experimental simulation of the space radiation environment, especially the investigation of the single event effect, the project of Xi`an Proton Application Facility (XiPAF) is under construction in Xi’an City, China. The facility is mainly composed of one 7 MeV H linac injector (Fig. 1), one Middle Energy Beam Transport line (MEBT), one 200 MeV six-fold synchrotron, two High Energy Beam Transport lines (HEBT) and two experimental stations. A flux of 10~10 p/cm/s with the non-uniformity of better than ±10% on the sample in the range of 1 cm×1 cm ~ 10 cm×10 cm is designed. The synchrotron will be operated with the slow-extraction mode to provide the proton beam with the pulse width of 1~10 s. The designed number of the accumulated protons in each pulse in the synchrotron is 1×10. Injection energy of 7 MeV is therefore determined to both achieve the accumulated particles in the synchrotron and limit the cost of the linac injector. The negative hydrogen ion beam is debunched to reduce the energy spread and strip-injected into the synchrotron. The parameter requirement of the linac injector is presented in Table 1. In this paper, the design result of the 7 MeV linac injector for the 230 MeV synchrotron of the XiPAF project is presented. Table 1: Requirement of the Linac Injector for XiPAF Parameter Value Unit