Combustion Test by Changing Bed Inventory on Circulating Fluidized Bed Boiler

YANG Jian-hua,YANG Hai-rui,YUE Guang-xi
DOI: https://doi.org/10.3321/j.issn:1000-6761.2009.06.002
2009-01-01
Abstract:Combustion tests were conducted by changing bed inventory on a 75 t/h circulating fluidized bed boiler.Within the bed pressure drop range of 3 220 Pa to 7 330 Pa,the influences of bed inventory on boiler load,axial particle concentration distribution in the furnace and actual combustion efficiency were tested.Results show that the boiler can still maintain full load operation under the condition of low bed pressure drop which is far from the normal bed pressure drop,and combustion is improved.It is concluded that under the condition of proper control of fuel particle sizes,operation of circulating fluidized bed boiler under low bed pressure drop is not only feasible,bus can also optimize the integral operational performance of the boiler.It is the tendency of boiler design and operation optimization.