Influence of the Coal Feed on the Bed Temperature Uniformity of a Large-sized CFB Boiler

MI Zi-de,LU Jun-fu
2012-01-01
Abstract:Compared with the traditional boiler types,the width/depth ratio of a large-sized CFB boiler will increase by a large margin and the influence of the bed temperature distribution characteristics at the lower portion of the furnance along the width direction on the boiler performance is even more remarkable.To identify the factors influencing the bed temperature at the lower portion of the furnace,the aurthors have designed and completed the bed temperature regualtion test under five different operating conditions in a large-sized utility boiler.The test results show that the non-symmetrical arrangement of the furnance outlet along the width direction leads to a relatively large flow state deviation in the right and left portion of the furnace.The cooling role played by the heating surfaces on both-side walls is deemed as the main causes for a conspicuous bed temperature gradient existing in a place nearing the side walls.The effectiveness to regualte the coal feed quantity at each coal feed ports at low loads is superior to that at high loads.In the design of a coal feed system,a certain allowance shall be considered for the coal feeders at both sides so as to meet the requirements for local bed temperature regualtion.