Effect of the Circulating Loop Performance on the Bed Temperature of a Circulating Fluidized Bed Boiler

Xue-qin MI,Xue-min LIU,Jun-fu LYU
DOI: https://doi.org/10.3969/j.issn.1672-4763.2013.05.006
2013-01-01
Abstract:Circulating fluidized bed(CFB)boiler is more advanced when the fuel is petroleum coke.The CFB boiler heat efficiency reaches 93%with CO emission of less than 60 mg/Nm~3. The original emission of NO_x is les than 20 mg/Nm~3 due to its higher carbon content and lower N in it.However,Nox emission depends strongly on the bed temperature as well as the excess air coefficient.Increasing the ratio of coal in the petroleum coke blend leads to the average ash contend in the fuel increasing,which will causes the increasing of solid bulk density in the furnace.And the bed temperature decreases when the input heat remains same.The theoretical prediction showed that the solid bulk density increases 20% results in the heat transfer coefficient increasing about 5%,which means the bed temperature decreases about 25℃.This prediction agrees well with the practice.Based on the theoretical analysis,a solution to increase the bed temperature is suggested to decrease the solid circulating rate to reduce the solid suspension density in the furnace,which is confirmed by the operation.