The Effect of the Emission in Circulating Fluidized Bed Boilers

LIU Zhi-qiang,LIU Qing,JIANG Wen-bin,XIAO Feng
2013-01-01
Abstract:The pollution control with low cost is the unique advantage of the circulating fluidized bed combustion technology.However,this advantage is exploited or not in the practices depends on the operation.The main effects of operation parameters on the SO2 and NOx emission were investigated in operating circulating fluidized bed(CFB) boilers,and the bed temperature is believed to be the key.SO2 and NOx emission of the existed CFB boilers are higher than expected is because of their higher temperature than design which is caused by the design fault.The investigation shows that the CFB boiler SO2 and NOx emission could be controlled less than 200 mg/Nm3 for the fuel of about 1% sulphur content when the bed temperature is strictly lower than 890 ℃ with the higher reactivity limestone of reasonable size distribution ranging from 150 to 300 micro and reasonable Ca/S radio.In the same time,the Oxygen content in flue gas at the outlet of the furnace is controlled lee than 2.5% with the lower bed temperature of 890 ℃,the initial NOx emission could be controlled less than 200 mg/Nm3.Therefore,the bed temperature of less than 890 ℃ is necessary for the CFB boiler to match the new National Emission standard of air pollutants for thermal power plants.
What problem does this paper attempt to address?