Experimental study of the bed Inventory overturn in pant-legs furnace of CFB boiler

Jin-jing LI,Nan HU,Xuan YAO,Shi YANG,Jun-fu LU
2011-01-01
Abstract:The pant-legs structure is widely used in furnace design of large scale CFB boiler.The bed inventory overturn in furnace usually causes shutdown accident.Based on the Scaling-Low proposed by Glicksman,the geometric size of a 300MW CFB boiler was scaled down,and a bench-scale CFB rig was built up to study the lateral solid flow in the pant-legs CFB riser.The across area and average height of the lateral solid flow were adjusted by a partition wall with a number of slots.The changes of bed pressures and air flow rates were recorded.The experimental results show that the hydrodynamic asymmetry between both sides of the furnace is the essential cause of bed inventory overturn.The prerequisite of bed inventory overturn is a dominate portion of the pressure drop caused by the bed inventory in the total pressure drop in furnace.The process of bed inventory overturn slows down when the across area and average height of lateral solid flow decreases.
What problem does this paper attempt to address?