Bed Inventory Overturn in A Circulating Fluid Bed Riser with Pant-Leg Structure

Jinjing Li,Wei Wang,Hairui Yang,Junfu Lv,Guangxi Yue
DOI: https://doi.org/10.1021/ef800835z
IF: 4.6541
2009-01-01
Energy & Fuels
Abstract:The special phenomenon, nominated as bed inventory overturn, in circulating fluid bed (CFB) riser with pant-leg structure was studied with model calculation and experimental work. A compounded pressure drop mathematic model was developed and validated with the experimental data in a cold experimental test rig. The model calculation results agree well with the measured data. In addition, the intensity of bed inventory overturn is directly proportional to the fluidizing velocity and is inversely proportional to the branch point height. The results in the present study provide significant information for the design and operation of a CFB boiler with pant-leg structure.
What problem does this paper attempt to address?