The Mechanism of Lateral Solid Transfer in a CFB Riser with Pant-Leg Structure

Jinjing Li,Hai Zhang,Hairui Yang,Qing Liu,Guangxi Yue
DOI: https://doi.org/10.1021/ef901338g
IF: 4.6541
2010-01-01
Energy & Fuels
Abstract:A bench-scale cold circulating fluidized bed (CFB) was set up according to the hydrodynamic scaling law to study the process of bed inventory overturn and the mechanism of lateral solid transfer inside the furnace of a 300 M We CFB boiler with pant-leg structure in the bottom. The experimental results show that the lateral pressure distribution inside the riser is nonuniform. Two possible mechanisms counting for the lateral solid transfer, i.e. solid diffusion mechanism and gas transport mechanism were discussed and analyzed. According to the experimental results, the motion of the solid particles is driven by the lateral pressure gradient of the gas phase in the bed, and hence is dominated by the gas transport mechanism. It is proposed that with pant-leg structure in the bottom furnace, the lateral pressure difference between two sides of the furnace and the axial pressure profile on each side of furnace should be monitored with the autocontrol system to avoid the bed inventory overturn.
What problem does this paper attempt to address?