AC Flashover Performance of Contaminated Insulators in Hot Water Vapor Washing

张晋,汲胜昌
DOI: https://doi.org/10.3321/j.issn:0253-987x.2009.12.020
2009-01-01
Abstract:The experiments of washing insulator contamination with hot water vapor are conducted to plot the average flashover voltage and flashover gradient curves of three insulators,calculate the flashover voltage,and analyze the influencing factors of flashover voltage.The results show that the flashover voltage and flashover gradient of FXBW4-35 insulators are highest,and those of XP-70 insulators are higher than FC-70 insulators.Power function can fit the flashover voltage of composite insulators washed by hot water vapor but not an optimum fitting function,the flashover voltage of insulators washed from bottom to top gets the highest.No overvoltage occurs to ensure the system security in the washing as the equivalent salt deposit density below 4×10-4g/cm2.
What problem does this paper attempt to address?