Electrochemical reclamation of silver from silver-plating wastewater using static cylinder electrodes and a pulsed electric field.
Yuan-Bo Su,Qing-Biao Li,Yuan-Peng Wang,Hai-Tao Wang,Jia-le Huang,Xin Yang
DOI: https://doi.org/10.1016/j.jhazmat.2009.05.096
IF: 13.6
2009-01-01
Journal of Hazardous Materials
Abstract:Silver was reclaimed from silver-plating wastewater by using a pulsed electric field (PEF) combined with static cylinder electrodes (SCE). The conditions that produced the maximal silver recovery rate (RRAg) (99%) were as follows: average retention time of 10min, interelectrode gap of 50mm, solution pH of 9.0, temperature of 45°C, initial Ag(I) concentration of 1000mgL−1, PEF pulse frequency of 1200Hz, current density of 5.0Am−2 and a pulse duty cycle of 60%. Compared with the conventional direct current (DC) technology, the PEF process exhibited improvements in the silver recovery rate (RRAg), total energy consumption (TEC) and physical properties of the silver deposits, especially for low Ag(I) concentrations, for example, from 500 to 1000mgL−1. For an initial Ag(I) concentration of 500mgL−1, the PEF process produced an RRAg of up to 99%, and the TEC was 4.56kWh(kgAg)−1. In comparison, the RRAg and TEC were 90% and 5.66kWh(kgAg)−1, respectively, in the DC process. The results of SEM observation and XRD analysis indicated that the silver deposits formed by the PEF process were smaller, denser, and of a higher purity than those produced by the DC process. Therefore, the presented method was effective for reclaiming silver from silver-plating wastewater.