Eddy Current Testing On Weld Defect Based On The Dual Frequency Independent Component Analysis

Chao Wang,Kai Wang,Zheng Cong,Ziqiang Cui
DOI: https://doi.org/10.1109/I2MTC.2017.7969919
2017-01-01
Abstract:Due to the textures and flatness problems of the welding under test, the lift-off distance of the detection probe varies during test, which constitutes the main error source in the NDT system. An eddy current detection probe that is composed of a rectangular excitation coil and a giant magnetoresistance device has been designed. The simulation results show that the effect of lift-off changes caused by the welding seam would be reduced to minimal in the case of the axis of excitation coil perpendicular to the welding seam. In addition, it suggests that the eddy current induced by the dual frequency excitation signal provides more effective information on the welding defect. Therefore, for further understanding and interpretation of the dual frequency information, the independent component analysis method is employed. Under the control of field programmable gate arrays board and two stepper motors, a displacement platform that carried the detection probe scanned the surface of the welding pieces, i.e. two aluminum-alloy plates, in which the frequencies of 500 and 4000 Hz are applied. The experiment results show that the influence of lift-off caused by the unflatness of the two plates can be reduced and the defect of diameter smaller than 1mm can be detected, showing that the proposed method helps enhance system capability in identifying the buried small defect.
What problem does this paper attempt to address?