Eddy Current Test/ultrasonic Testing Integrative Method for Detecting Sub-Surface Defects in Conductive Structures

LIU Ban-teng,LUO Xu-wei,HUANG Ping-jie,HOU Di-bo,ZHANG Guang-xin
DOI: https://doi.org/10.3785/j.issn.1008-973x.2017.04.007
2017-01-01
Abstract:An integrative nondestructive testing (NDT) method based on the eddy current testing (ECT) and ultrasound testing (UT) was analyzed for the problem of limited detection accuracy and range of single detection method for conductive structure sub-surface defects inspection.The techniques for calculating the ECT/UT basic probability distribution, the distribution of weights of evidence and the evidence fusion to obtain accurate identification results were investigated in order to solve the problem of heterogeneous evidence confliction and to fully exploit the advantages of individual modality detection method.A data fusion method based on fitting variance optimized D-S evidence theory was proposed.A normal fitting method based on the Akaike information criterion (AIC) was conducted to gain the basic probability distribution curve of ECT/UT data in order to reduce fitting errors and prevent over-fitting problems.The Bayesian criteria were used to calculate the posterior probability according to the applicability of ECT/UT in the detection.The fitting variance was used for evidence weight optimization.The joint probability density distribution was obtained by D-S evidence theory.The ECT/UT integrative test result was calculated.
What problem does this paper attempt to address?