Pressure Drop Of Steam Condensation Flow In Vacuum Horizontal Tube For Lt-Mee Desalination Plant

Yaoxuan Wang,Xingsen Mu,Shengqiang Shen,Wenjie Zhang
DOI: https://doi.org/10.5004/dwt.2017.0468
IF: 1.1
2017-01-01
Desalination and Water Treatment
Abstract:An experimental system was built up to measure the pressure drop of steam condensation flow in vacuum horizontal aluminium brass tubes, whose inner diameter is 18 mm and length is 2 m. The experiments were carried out at the saturation temperatures varying from 50 degrees C to 70 degrees C with mass flow rate changing between 2 and 11 kg/(m(2).s). The temperature differences between steam and cooling water are 3 degrees C, 5 degrees C and 7 degrees C, respectively. Pressure drop decreases along flow direction. Pressure drop increases with mass flow rate and vapor quality, decreases with saturation temperature. Temperature difference has less effect on pressure drop. The saturation temperature depression rises at first and remains at a constant level later with the increase of flow direction. Saturation temperature depression increases with mass flow rate and decreases with temperature difference and saturation temperature. Based on the experimental data, a correlation was proposed for calculating pressure drop of steam condensation flow in vacuum horizontal tube.
What problem does this paper attempt to address?