Fouling Characteristics of Coal Biomass Co-Combustion and the Influence of the Deposition Surface

Hao Zhou,Jiakai Zhang,Weichen Ma,Yong Xu,Menghao Zhao
DOI: https://doi.org/10.1021/acs.energyfuels.7b00108
IF: 4.6541
2017-01-01
Energy & Fuels
Abstract:Fouling deposition is a severe problem in boilers, especially co-firing coal with biomass. In this study, the influences of the deposition surface on the fouling mitigation and heat flux through the surface of the heat transfer tube are investigated. Chromium (Cr) was coated on the surface of the heat transfer tube; an online measurement is applied to monitor the growth of the fouling deposit. Meanwhile, mineralogy and microstructure of the deposits are obtained by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The results showed that average thickness of the fouling deposits decreased from 11.09 to 4.32 mm and the average heat flux increased from 238.93 to 261.11 kW/m(2) with the surface of the heat transfer tube coated with Cr. The XRD results showed that the content of sodium, which has a great effect on the adhesion force, is reduced with the surface of the heat transfer tube coated with Cr. Consequently, the Cr coating showed good performance in reducing the fouling deposition.
What problem does this paper attempt to address?