Lightning Protection System of Traction Power Supply System for High-speed Railway
ZHOU Lijun,GAO Feng,LI Ruifang,CAO Xiaobin,WU Guangning
DOI: https://doi.org/10.3969/j.issn.1003-6520.2013.02.021
2013-01-01
Abstract:In order to improve the lightning protection performance of power supply systems for high-speed railways,the defects of existing lightning protection system of high-speed railways were discussed,and the lightning characteristics of high-speed railway traction power supply system were analyzed based on electrical geometric models and measured data.It is found that the number of direct lightning strokes on a viaduct with average height of 16 m is nearly as 2 times as much as that without viaduct.Since the induced overvoltage caused by lightning surrounding of lines can be ignored,traditional ways of induced lightning protection have little effect.With the increasing viaduct height,the proportion of insulator flashovers caused by direct lightning strokes and induced lightning among all insulator flashovers increases continuously.Moreover,some improvement methods of lightning protection for high-speed railway power supply systems,like adopting reserved special grounding wires,are proposed.Meanwhile,the difference between the lightning protection system and the anti-counterattack-lightning protection of tradition transmission power systems reveals that,with a viaduct height of 16 m and an impulse grounding resistance of integrated grounding system less than 3.9 Ω,the threat of induced lightning is more than that of counterattack lightning.