Peaking capability and economic analysis for a 330 MW cogeneration unit

Yu ZHU,Qianjun LI,Yongxin FENG,Shumei WU,Yanfen LIAO,Xiaoqian MA
DOI: https://doi.org/10.3969/j.issn.1002-3364.2014.06.007
2014-01-01
Abstract:Taking a typical double extraction 330MW cogeneration unit as the research object,the variable condition model was built by applying the equivalent enthalpy drop method.On the basis of this model,the operation characteristics of this unit under pure condensing condition and extraction condition were investigated.The economic efficiency and peaking capacity of this unit under above two conditions were obtained.The results show that:under pure condensing condition,the low-pressure cylinder inner efficiency under 50% load condition was 71%,about 2.9% lower than that under 100% condition;the pure condensing condition had the strongest peaking capability(with a rate of 163MW),but the lowest economy;the peaking rate of double extraction condition was only 79MW,which was the lowest;when one extraction flow rate was constant,the turbine power generation thermal efficiency increased with the other extraction flow rate.