THE INFLUENCE OF PRETIGHTENING FORCE OF FOUNDATION ANCHOR ON SHEAR RESISTANCE, PART Ⅱ : RIGID COLUMN BASE

Yuan-qing WANG,Jun ZHANG,Yong-jiu SHI,Hong CHEN
DOI: https://doi.org/10.3969/j.issn.1001-6864.2005.03.014
2005-01-01
Abstract:Code of design of steel structure and technical specification for steel of light-weight buildings with gabled frames clearly stipulate that the foundation anchor can't receive horizontal shear of column base.The frictional force between base plate and concrete foundation or shear lugs can receive it.If μ N is less than V,the shear lugs must be installed in column base,where only axial force was taken into consideration.In fact, pretightening force exists in anchors of column base.If the pretightening force is taken in to account,the shear resistance of column base will increase.Based on the FEM model of hinged column base,this paper calculates the shear resistance of column base under several different pretightening force of foundation anchor,and analyzes the influence of pretightening force.According to the results,the shear lugs must be installed in column base if μ F is less than V.