FEM ANALYSIS OF RESISTANCE OF REINFORCED BEAM-TO-COLUMN CONNECTION WITH COVER-PLATE UNDER LOADS IN STEEL FRAME

Hui Cao,Yuanqing Wang,Yannian Zhang,Tianshen Zhang,Ming Liu
DOI: https://doi.org/10.13204/j.gyjz201702005
2017-01-01
Abstract:In order to study the seismic performance of the beam-to-column connections reinforced with cover-plate in steel frames and provide a reference for the new technical specification for strengthening steel structures, the FEM analysis under cycling loading for four beam-to-column connections with different initial loading was carried out to study the failure modes,limited resistance,hysteretic behavior,ductility, energy dissipation capacity,stiffness degradation of the connections, which were compared with unreinforced connections.The result showed that the reinforcement could effectively improve the limited resistance and ductility of the connections, which made plastic hinge shifts away a quarter of the beam height from the cover-plate end, thus avoiding the damage at the weld location and achieving the purpose of the reinforcement.
What problem does this paper attempt to address?