Analysis of Bolt Tensile Force and Prying Force in Extended End-Plate Beam-to-Column Bolted Connections

JIN Xiaoqun,ZHAO Wei,TONG Genshu
DOI: https://doi.org/10.3969/j.issn.1001-7119.2008.03.015
2008-01-01
Abstract:Bolt force is affected by bolt prying force considerably,and the knowledge about the role of bolt prying force is inadequacy.The finite element method is used to analyze the bolt tensile force and bolt prying force in extended end-plate bolted connections.The moment-bolt tensile force curves,prying force distribution and change patterns are presented.And the influences of end-plate thickness and end-plate stiffener are compared.The comparison shows that the end-plate stiffeners,especially the larger stiffeners,are more effective to decrease bolt prying force than end-plate thickness.Based on the finite element data,kinds of bolt force theories are evaluated.
What problem does this paper attempt to address?