TENSILE PERFORMANCE AND DESIGN METHOD OF ULTRA-LARGE CAPACITY END-PLATE CONNECTIONS

陈学森,施刚
DOI: https://doi.org/10.13204/j.gyjz201706030
2017-01-01
Abstract:The ultra-large capacity end-plate connection is a newly-proposed beam-to-column connection form that can be adopted in steel frame with long span or heavy load.In seismic regions beam-to-column connections in frame may suffer considerable tension force besides the moment, so it is necessary to analyze the tensile performance of the ultra-large capacity end-plate connections.Four full-scale specimens of ultra-large capacity end-plate connections with different end-plate thicknesses, bolt diameters or bolt layouts were tested under tension loads, and the distribution of the axial strain increment in the bolts were recorded and analyzed.A total of 24 finite element models were established to further analyze the tensile performance of the connection form.Based on the results of the experiments and the finite element analysis, the bolts close to the middle of the beam flanges in the extended parts were the most dangerous ones under axial tension, and removing the corner bolts made no adverse influence to the tensile performance.A recommended formula to calculate the effective bolt number in tension was proposed, and the design method for the tensile bearing capacity of the connection was provided.
What problem does this paper attempt to address?