Experimental study on seismic behavior of precast concrete column with longitudinal reinforcement grouting-anchoring connections

Chen Jun,Xiao Yan
DOI: https://doi.org/10.15951/j.tmgcxb.2016.05.006
2016-01-01
Abstract:Connections between precast concrete column and foundation can be achieved by inserting the extended longitudinal reinforcement in precast concrete column into the corrugated pipe with high-strength filler.In this study,a low-frequency cyclic loading test was conducted for eight precast concrete columns and one integral cast-in-place column for comparison.The main investigated influencing factors include the axial compression ratio,the strength grade of column stirrup,and the bonding condition of steel bar and concrete within the range of 5d (d is the diameter of steel bar) from the column base.Experimental results indicate that the energy dissipation coefficients of the precast columns connected by the proposed method are similar to those of the integral cast-in-place columns,but the ductility factors of these precast columns are greater than those of the integral cast-in-place columns.After the bondless treatment within the range of5d from the column base,the ductility factors of columns can be increased by 18% ~25% and the energy dissipation capacity can be increased by 13% ~ 20%.By increasing the strength grade of stirrups,the ductility factors of columns can be increased by 5% ~ 10%,and the dissipation capacity can be improved by 8% ~ 16%.
What problem does this paper attempt to address?