STUDY ON PROBLEMS OF SCALING AND CLOGGING IN WET CALCIUM FLUE GAS DESULFURATION FACILITY OF MEDIUM-AND SMALL-SCALE INDUSTRIAL BOILERS

李丹,李立清,陈昭宜,宋剑飞
DOI: https://doi.org/10.3969/j.issn.1002-3364.2004.06.008
2004-01-01
Abstract:An approach to problems of scaling and clogging etc. which affecting the operation of wet calcium flue gas desulfuration (FGD) facility for industrial boilers has been carried out, and concrete quantitative computation being made, obtaining the range of pH value having to be controlled. In order to control the pH value of desulfuration liquid, an intelligent online pH value controller can be installed in the said system; in addition, a gravity type dehydration tank can be added in the system, using the dust contained in the tank to filtrate solid matters produced in the said system, ensuring further to prevent the system from scaling and clogging. Practice shows that the developed scheme of antiscaling andclogging to be feasible.
What problem does this paper attempt to address?