Analysis of overcurrent fault occurred when electric mining haul truck brakes

Guan-hua CHEN,Li-qiang YUAN,Ri-long YANG,Wen-sheng WANG,Zheng-ming ZHAO
DOI: https://doi.org/10.3969/j.issn.1003-3076.2014.10.003
2014-01-01
Abstract:Huge electric mining haul trucks are widely used in mining industries,which greatly increases the efficiency of ore transportation in mines. Overcurrent faults easily occur in the motor drive system when trucks brake in high speed area. As the limit of hardware of the system,traditional debug method is no longer accessible. In this paper,a new overcurrent fault analysis method based on reverse technology is proposed,which is to get the realtime value of voltage space vector in the control program from the measured real-time inverter output voltage. In the overcurrent fault case in this paper,this method is applied and it proves that the sudden drop of transient frequency of voltage space vector causes overcurrent,which are because of the electromagnetic interference of speed feedback signal after further analysis. Detailed solution is given to solve this problem. Experiment proves the effectiveness of the solution.