Experimental study on factors affecting the ammonia-based WFGD process

Honglei DING,Qiufeng Su,Yongxin Zhang,Wen Wen,Xiang GAO
DOI: https://doi.org/10.3969/j.issn.1002-3364.2014.01.096
2014-01-01
Abstract:Aiming at investigating the ammonia-based wet flue gas desulfurization(WFGD) process,the influence of process parameters on desulfurization efficiency was experimentally studied on a small scale countercurrent spray tower FGD system,under cold state condition.The results indicated that,the desulfurization efficiency was mainly affected by pH value,which increased from 69.6%to 94.1% when the pH value rose from 4.5to 5.0.The optimal pH value varies from 5.5to 6.0.Properly increasing the residence time of flue gas and enhancing the liquidgas ratio was helpful to the desulfurization efficiency.However,the desulfurization efficiency dropped when the inlet SO2 concentration was increased.