Research on New Style of Prestressed Cables for Gate Pier

逄阿强,马吉明,佟志强
DOI: https://doi.org/10.3969/j.issn.1003-1243.2004.03.016
2004-01-01
Abstract:With investigation of the application of the prestressed pier with high thrust,a new idea of research on the style of the flexural unbonded prestressed cable is presented in this paper.Based on the data of Xihe hydropower station,FEM analysis about the stress state of the arc-gate pier with high thrust has been done and achieved with the help of the structure-analyzing software MSC/Nastran.For the analysis,the flexural cables were placed along the trace of maxi principal stresses in the pier and anchor block,the concrete was prestressed in the tension area of the pier neck which is connected by the pier with the anchor block.Study of concrete prestressed effect has been made to contrast the new style cable with the traditional linear bonded prestressed cable.As the result of the contrast,the effect of the flexural unbonded prestressed cable is better.
What problem does this paper attempt to address?