The Measurement and Correction of Correlation Formulas of Flue Gas Acid Dew Point

Bai-xiang XIANG,Wen-chong XING,Jian-feng LI,Yu-zhong LI,Hai-rui YANG,Jun-fu LYU
DOI: https://doi.org/10.3969/j.issn.1672-4763.2014.01.001
2014-01-01
Abstract:In order to avoid the fouling and corrosion of heating surface,the exhaust flue gas temperature is controlled higher than its acid dew point.Recently,the exhaust flue gas temperature is expected to decrease to increase the energy efficiency,which requires the acid dew point should be predicted more accurately.However,the prediction results with the current semi-empirical correlation formulas are higher.Thus,the effect factors on flue gas acid dew point are analyzed,and the measurements are conducted in a real boiler with the flue gas acid dew point meter developed by Tsinghua University.In the same time,SO3 concentration is also measured with a new method based on SO3 can be absorbed by saturated NaHSO3.According to the measurement results,a corrected correlation formula of flue gas acid dew point is suggested,which considers the function of SO3 concentration as well as H2 O concentration.
What problem does this paper attempt to address?