MEASUREMENT OF SO2 AND SO3 IN SCR FLUE GAS DENITRIFICATION

Ning Wu,Qiang Song,Shuiqing Li,Qiang Yao
DOI: https://doi.org/10.3969/j.issn.1004-4248.2006.02.020
2006-01-01
Abstract:A method to measure the concentrations of SO_2 and SO_3 in flue gas simultaneously was built. Three collection stages were designed to collect SO_x in gas and the amount of SO_3~ 2- and SO_4~ 2- formed in the absorbent solution was analyzed by ion chromatography to determine the the concentrations of SO_2 and SO_3 in gas. The measurement errors for SO_2 and SO_3 were 1.2% and 29.6% respectively.Catalytic reduction of NO and catalytic oxidation of SO_2 with self-prepared V_2O_5/WO_3/TiO_2 catalyst were studied by this method. The experimental results showed that denitrification rate and oxidation rate of SO_2 increased with the increase in reaction temperature.The optimum reaction temperature for flue gas denitrification ranged in 310 ℃-400 ℃, with the consideration of both denitrification and SO_2 oxidation.NH_3 and NO in flue gas competed with SO_2 for adsorption on the surface of catalyst,and decreased the oxidation rate of SO_2.
What problem does this paper attempt to address?