Kinetic modelling and experimental studies on SO3 generation in flue gas for coal-fired boiler

Baixiang XIANG,Hairui YANG,Junfu Lü
DOI: https://doi.org/10.11949/j.issn.0438-1157.20170052
2017-01-01
Abstract:Various harms on equipment and atmospheric environment, including low-temperature corrosion, fouling and blue plumes, can be caused by SO3 in flue gas for a coal-fired boiler. To predict and control SO3 concentration to meet the increasing demands for energy conservation and emission reduction, more accurate knowledge on the effect of the factors that influence SO3 in flue gas is required. Thus, in present work, a kinetic model was built by optimizing the previously developed kinetic models. The effect of the factors that influence SO3 in flue gas was studied by numerically calculating SO3 concentration under different conditions. Moreover, SO3 concentrations under the conditions mentioned above were measured using a perfectly stirred reactor measuring apparatus built in this work. It was found that SO3 concentration was apparently affected by the factors, namely, the concentrations of SO2, O2 and H2O, as well as temperature and residence time. SO3 concentration was seemingly affected by the concentrations of CO and NO, while was less influenced by CO2 concentration. In addition, SO3 concentration underwent three stages of sharp increase, slow increase and gradual decrease with increasing residence time.
What problem does this paper attempt to address?