Measurements of Dew Point Temperature of Flue Gas in Circulating Fluidized Bed Reactor for Flue Gas Desulfurization

王晓芳,佟会玲,马千里,李定凯
DOI: https://doi.org/10.3969/j.issn.1671-4628.2003.05.004
2003-01-01
Abstract:Industrial-scale experiments of flue gas desulfurization (FGD) in a circulating fluidized bed (CFB) reactor were conducted. The nominal flue gas flow-rate through the reactor was 20?000?Nm 3/h. Two methods for measuring the dew point temperature of the flue gas were used in the experiments: capacitive sensor online inspection and measurement of gas dry/wet bulb temperatures. A new method for measurement of wet bulb temperature was adopted during the experiments to increase the measurement accuracy. Based on the results of above flue gas dew point measurements, a method for data correction was put forward, i.e. to minimize the sum of square deviations of the dew point temperatures measured by the two methods and linearly fit the two data sets by the least square method. Using the fitting results, the online measurement of flue gas dew point temperature was revised, and more exact flue gas dew point temperature at the exit of the CFB reactor was acquired.