Galvanic Corrosion Behavior of Couples of Hot Rolled Steel SS400 and Cold Rolled Steel ST12 with Two Coatings

ZHAO Xiaohong,GUO Quanzhong,DU Keqin,GUO Xinghua,WANG Yong
DOI: https://doi.org/10.11902/1005.4537.2013.258
2015-01-01
Abstract:Galvanic corrosion behavior of couples of cold rolled steel SS400 and hot rolled steel ST12 with chrome-free Zn/Al coating or Zn/Ni alloy electroplating was studied in 3.5%NaCl (mass fraction) solution by means of potentiodynamic polarization and galvanic method. The results showed that the couple of SS400 and ST12 with Zn/Ni alloy electroplating exhibited a weaker ten- dency of galvanic corrosion, a higher open circuit potential and a smaller galvanic current rather than that with chrome-free Zn/Al coating. While the free-corrosion current of Zn/Ni alloy electro- plating coating was smaller than that of Zn/Al coating. Therefore, Zn/Ni alloy electroplating is ex- tremely promising coating for the auto-mobile fastener to replace the traditional Zn electroplating.
What problem does this paper attempt to address?