Abstract:In this paper, finite element model of SiCp /Al single cell body and single diamond particles were established by cross-scale modeling method. The results shows that the extent of damage of SiC particles increased with the increase of amplitude and frequency; The integrity of SiC particles are still better under the ultrasonic frequency 20000 Hz and the maximum amplitude 5um,so the optimal frequency range of ultrasonic scratch is (20000-30000)Hz. As for 22000 Hz, the integrity of SiC particles was better under the amplitude 4um,while the SiC particles have a significant damage in the border area under the amplitude 5um,so the best frequency and amplitude for ultrasonic scratches are: 22000 Hz and 4 um.
What problem does this paper attempt to address?