Investigation and Suppression of Current Zero Crossing Phenomenon for a Semicontrolled Open-Winding PMSG System

Heng Nian,Yijie Zhou
DOI: https://doi.org/10.1109/tpel.2016.2523252
IF: 5.967
2016-01-01
IEEE Transactions on Power Electronics
Abstract:The semicontrolled open-winding PMSG system has been widely investigated due to its simplified topology and easy control implementation. Nevertheless, compared with the conventional controllable converter structure, the current zero crossing phenomenon will last a longer time in the semicontrolled configuration, which is determined by the phase displacement between voltage and current. Since a long current zero crossing duration will lead to voltage pulse disturbance, serious electromagnetic interference, and output power fluctuation, it is necessary to reduce the zero crossing duration to improve the open-winding PMSG performance. This paper gives a detailed analysis on the zero crossing phenomenon of the semicontrolled open-winding PMSG system in the 3-D space vector modulation perspective. Meanwhile, a third harmonic injection method is suggested to reduce the zero crossing duration. It is also demonstrated that the torque and power pulsation are effectively improved, while the zero-sequence current amplitude does not increase. A proportional resonant controller is used to regulate the desired zero-sequence current. The proposed method is validated in a 1-kW semicontrolled open-winding PMSG experimental system with id = 0 control method.
What problem does this paper attempt to address?