Improved Method for Real-Time Fluence Monitoring in UV Reactors

Mengkai Li,Zhimin Qiang,James R. Bolton,Wentao Li,Chen Wang
DOI: https://doi.org/10.1061/(asce)ee.1943-7870.0000909
IF: 2.479
2015-01-01
Journal of Environmental Engineering
Abstract:Based on previously developed monitoring system comprising three microfluorescent silica detectors, this paper proposed an improved real-time fluence monitoring method for running ultraviolet (UV) reactors. Adoption of this new method would significantly decrease the number of biodosimetry tests while increase the monitoring accuracy. The method constants were first determined by biodosimetry; thereafter, a long-term (about 16 months) experiment was conducted to evaluate the continuous performance of the proposed method under simulated practical conditions. The results indicate that the daily average fluence dropped gradually from 248 to 30 mJ/cm(2) over the whole operational period, which arose principally from the lamp output attenuation and serious sleeve fouling. Furthermore, the real-time monitoring data of 1 representative week were analyzed, which could provide useful instructions for the operation and maintenance of UV facilities. This paper demonstrates that the proposed method could monitor well the real-time fluence with a low cost but a high accuracy. (C) 2014 American Society of Civil Engineers.
What problem does this paper attempt to address?