Estimating the Fluence Delivery in UV Disinfection Reactors Using a ‘Detector-Model’ Combination Method

Zhimin Qiang,Mengkai Li,James R. Bolton,Jiuhui Qu,Chen Wang
DOI: https://doi.org/10.1016/j.cej.2013.08.024
IF: 15.1
2013-01-01
Chemical Engineering Journal
Abstract:Current mathematical models for estimating the fluence delivery in an annular ultraviolet (UV) disinfection reactor are not adequate because some critical input parameters (e.g., lamp output, sleeve transmittance, and water temperature) concerning various reactor characteristics are difficult to quantify. In this study, a fluence rate (FR) model (UVCalc® version 2A), combined with experimental measurements using an FR detector, namely a 360-degree response micro-fluorescent silica detector (MFSD), was used as a new method to determine the practical fluence. The FR values at representative test points were measured by the MFSD in the temperature range of 10–30°C and water transmittance range of 85–95% (per cm). The radius-weighted average of the measured to model FR ratios at these test points was adopted as a ‘correction factor’ to calibrate the model fluence (i.e., reference fluence) to the practical fluence at a certain water temperature and UV transmittance. The fluences estimated by the ‘detector-model’ combination method agreed well with those determined by biodosimetry. This fast and cost-effective method has potential applications for estimation and on-site inspection of the practical fluence in UV facilities.