On the Heat Conduction Losses of Pulse Tube and Regenerator at Temperature Range of 300-4K

YL Ju
DOI: https://doi.org/10.1063/1.1472115
2002-01-01
Abstract:Performance predictions of pulse tube coolers involve estimating pressure drop and heat transfer to determine regenerator efficiency under oscillating flow and oscillating pressure conditions. This paper discusses the enhanced heat conduction of helium gas in the pulse tube and regenerator by the oscillations. It shows that the helium gas confined in the pulse tube as well as in the void volume of the regenerator can produce enhanced heat conduction at a rate an order of magnitude greater than by pure gas conduction, provided the gas is oscillated sinusoidally. Thereby, the effective coefficient of thermal conductivity of the gas in the regenerator is typically an order of magnitude larger than the pure gas conductivity; while the effective coefficient of thermal conductivity of the regenerator material is typically an order of magnitude less than the bulk value. In practical pulse tube coolers, the effective heat conduction losses of the helium gas, solid wall, and regenerator materials are typically of the same order of magnitude.
What problem does this paper attempt to address?