Study On Pulse Tube Refrigeration Performance With Two-Component Gas Mixture

Zh Gan,Jp Yu,Gb Chen
1998-01-01
Abstract:In order to increase the cooling capacity of the pulse tube refrigerators at 80K temperature region, the possibility of using two-component gas mixture instead of pure helium is theoretically analyzed in this paper. Two groups of gas mixture are recommended. One is helium-neon, helium-hydrogen or neon-hydrogen, which still remains gas state at 80K temperature region. The other is helium-nitrogen, neon-nitrogen or hydrogen-nitrogen, which is in a two-phase state at 80K when the molecular fraction of the nitrogen component is less than 10%. The performance of the pulse tube refrigerators may be improved in the sight of enthalpy difference.
What problem does this paper attempt to address?