Failure Analysis on Abnormal Thinning of Elbows in the Economizer at Waste Heat Boiler System

shenghui wang,xiaoming luo,yuqing yang,jian tang,zhenguo yang
DOI: https://doi.org/10.1115/PVP2015-45251
2015-01-01
Abstract:Abnormal wall thinning of elbows were detected in the economizer at waste heat boiler system. In the failure analysis, material analysis, metallographic examination, macro- and microstructure analysis and composition analysis were conducted. We analyzed the causes and mechanisms of abnormal wall thinning. The failure causes were found to be sulfuric dew point corrosion. Finally, corresponding countermeasures were suggested.
What problem does this paper attempt to address?