Suitable Water Flow And Water Temperature Difference Of Blast Furnace

haibin zuo,qian li,jianliang zhang,meng shen,jinyan tie,kexin jiao
DOI: https://doi.org/10.1007/978-3-319-48217-0_83
2015-01-01
Abstract:This paper designs three factors such as temperature, pH, conductivity and three levels of orthogonal test. Temperature is a significant factor. However PH and conductivity are not significant through poor analysis. Further research is conducted on the temperature. Temperature stability is 50 degrees C Suitable water velocity is 2.3m/s, which is calculated based on the largest part of the heat flux intensity and the corresponding water temperature should be controlled with 1.5 degrees C. Meanwhile, water velocity increased has little effect on the heat transfer capabilities.
What problem does this paper attempt to address?