Influence study on blast furnace cooling water quality by ultrasonication treatment

Zhijun He,Hao Guo
2012-01-01
Abstract:This paper focused on the ultrasonication treatment on blast furnace circulating water, which adopting the orthogonal method to research the variation of Ca2+ concentration in different ultrasonic frequency, power and velocity of circulating water. The results indicated the primary sequence is ultrasonic frequency, velocity of circulating water and ultrasonic power, the best combination is ultrasonic frequency :30kHz, velocity of circulating water: 0.6m/s, and ultrasonic power :400W(100W/cm(2)). Analysis the relation between ultrasonic frequency, ultrasonic power and time under ultrasonication, the Ca2+ concentration is 84.2 mg/L when the ultrasonic frequency 30kHz, velocity of circulating water 0.6m/s and ultrasonic power 400W, the effect of anti-scaling is obviously. The regression function of electric conductivity to lime under ultrasonication is: Y=-250.11nx+1352.6, R2=0.9877. When ultrasonic power at 400W, the energy consumption is 3.571kW/h, and the test time is 8 hours, the efficiency is 89.6%.