Aging Characteristics of Inverter-fed Motor Twisted Pair Using Tanδ

WU Guang-ning,ZHOU Li-ren,GUO Xiao-xia,HE Jing-yan
2010-01-01
Abstract:The failure of enameled wire used in inter-turn insulation of inverter-fed motor winding is the main reason leading to the motor insulation breakdown. The enameled wire used in inter-turn insulation of JD117 inverter-fed motor was experimentally researched by focusing on twisted pairs as test object. Bipolar pulse voltage aging test was conducted under various frequency and time,and dielectric frequency and temperature spectra of specimen were measured and analyzed.Moreover,combining with scanning electrical microscope (SEM),the influence of different aging conditions on surface morphology was researched. The experiment results reveal that with the deepening of aging degree,through analyzing frequency spectrum of tanδ,its peak value can be used to judge the insulation condition. Aging will change the structure of material internal,for long-chains are fractured leading to the formation of polar molecules with low molecular weight,therefore,relaxation polarization is more easy to be established. The more severe the aging is,the more material internal defects are created resulting in the easier formation of defective polar particles and greatly increasing dielectric loss. There exists significant difference of surface morphology of twisted pair between non-aging and aging,and the difference becomes increasingly evident with the deepening of aging degree.
What problem does this paper attempt to address?