Analysis of Aging Properties for Insulation Based on Statistical Parameters of Partial Discharge Under Pulse Voltage

Zhou Kai,Wu Guangning,Wu Jiandong,Liu Jun,Liu Xi
DOI: https://doi.org/10.3321/j.issn:1000-6753.2008.04.002
2008-01-01
Abstract:Properties of partial discharge (PD) of magnetic wires for interturn insulation and insulation to ground are investigated at different aging time under pulse voltage. Through phase resolved PD patter with aging time, clusters of discharge number occurred with increase of aging time. Comparing the results of phase resolved PD patter at 50Hz AC and pulse voltage, no similar phenomena are observed at 50 Hz AC voltage. Behaviors of PD for two different types of winding wires are compared, and internal void discharge played the leading role for winding wires for interturn insulation, and PD of winding wires for insulation to ground is mainly caused by slot discharge. Furthermore, statistical parameters of partial discharge (e.g., skewness, kurtosis, degree of asymmetry) in wingding wires at different aging time are also obtained in order to show relationships between partial discharge statistical parameters and aging time. After detailed analysis, we can conclude that there is a strong relation between skewness of mean discharge quantity and aging time. These conclusions could be used to further investigate properties of aging under pulse voltage.
What problem does this paper attempt to address?