Effects of Thermal Aging on the Electrical Properties of Magnetic Wire Insulation in Inverter-Fed Traction Motor

Qinxue Yu,Wene Ren,Lisheng Zhong,Enguang He
DOI: https://doi.org/10.3969/j.issn.1009-9239.2014.01.025
2014-01-01
Abstract:In order to study the degradation influence factors of inverter-fed traction motor magnetic wire insulation, magnetic wires were thermal aged at 300 ℃, and the change law of their dielectric loss fac-tor, capacitance, current increment, insulation resistance and breakdown voltage with the aging time was analyzed. The results show that with the increase of thermal aging time, the dielectric loss factor, capaci-tance and current increment increase, insulation resistance decreases, and the breakdown voltage changes little, therefore the residual breakdown voltage cannot be used to equal the residual life. The diagnostic index can be used as a new parameter to evaluate the aging degree of magnetic wire.
What problem does this paper attempt to address?