Aging Characteristics Analysis of Inter-turn Insulation Using Dielectric Loss

HE Jing-yan,WU Guang-ning,GAO Bo,LEI Ke-gang
DOI: https://doi.org/10.3969/j.issn.1003-6520.2007.08.039
2007-01-01
Abstract:Contrast aging tests are carried out on twisted pairs simulating inter-turn insulation of inverter-fed traction motor under AC and square wave pulse conditions.The variety of tan δ subjected to various aging factors with aging time and measuring voltage are investigated.The differences of dielectric loss between AC aging and square wave pulse aging are studied based on change curves of tan δ combining the results of thermally stimulated current(TSC).When measuring voltage is Un,the PD and space charge result in a sharp increase of insulation defects.When measuring voltage is 0.2Un,the eject and inject of space charge result in a damage of insulation.Both of them cause that tan δ under square wave pulse aging is bigger than that under AC aging.Space charge is likely to be the key factor resulting in breakdown of insulation materials under continuous impulses.
What problem does this paper attempt to address?