How to Analyze Aging Characteristics of Generator Main Insulation Based on Mechanical and Dielectric Loss

Jia Zhidong,Hao Yanpeng,Jiang Xiongwei
2017-01-01
Abstract:The main insulation (stator winding insulation) of large generator is an important component of generator and its availability and remaining lifetime depend to a large extent on the conditions of main insulation. At present, the system of epoxy mica insulation is mostly used. Against the aging problem of main insulation during the running, the epoxy mica insulation material is used to carry out the aging test under the influence of electric and thermal stress or mechanical stress; a new analysis method dynamic mechanical analysis (DMA) is adopted to measure aging characteristics of insulation materials; dynamic mechanical parameters are compared with that of dielectric loss. The DMA should be used to describe the aging characteristics of epoxy mica insulation.