Dielectric Loss Study of Inverter-fed Traction Motor Twisted Pair

Liu Jiwu,Zhou Lijun,Wu Guangning,Luo Yang,Peng Jia,Zhu Guangya
DOI: https://doi.org/10.3969/j.issn.1009-9239.2013.01.013
2013-01-01
Abstract:Three dielectric loss-voltage(tanδ-U) curves of inverter-fed traction motor twisted pair after experiencing thermal aging,electrical aging and electrical-thermal aging were tested separately;and then compared with the tanδ-U curve tested under high temperature.The tanδ-U curves of the twisted pair under different aging degrees were also tested.The results show that the corresponding voltage of turning point in the first tanδ-U curve is obvious larger than that of the latter two tanδ-U curves of the twisted pairs after thermal aging and electrical-thermal aging.It is verified that the corresponding voltage of turning point is the partial discharge inception voltage(PDIV) of the twisted pair.With the deepening of the aging degree,the corresponding voltage of turning point in the first tanδ-U curve increases.
What problem does this paper attempt to address?