Traction Inverter Highly Accelerated Life Testing With High-Temperature Stress

Qunfang Wu,Mengqi Wang,Weiyang Zhou,Xi Lu,Kewei Xiao,Krishna Prasad Bhat,Chingchi Chen
DOI: https://doi.org/10.1109/tte.2020.3006778
IF: 6.519
2021-03-01
IEEE Transactions on Transportation Electrification
Abstract:Highly accelerated life testing (HALT) is one of the most popular step-stress testing methodologies for identifying the weaknesses and increasing product reliability in a fast and cost-efficient way. The traction inverter plays a critical role in EV/HEV power train systems, and the requirements on its reliability at the harsh environment operation are becoming more demanding. In this article, to evaluate the weak links and various components performance and ascertain the effect of high temperature on the traction inverter, the traction inverter HALT was carried out with high-temperature stress between 190 °C–220 °C taking the IGBT on-die temperature as the benchmark. Nine traction inverters were tested, which were divided into four groups with respect to the designed step-stress test profile. The changes in electrical and thermal indicators were observed online using the proposed monitoring system. At the end of each test, the effects of different conditions on the overall testing time, failure modes, and damage were examined, and the damages were listed systematically and discussed. Furthermore, the characteristics of the dc-link capacitor at different temperatures and the related degradation were observed online. The results show that the inverter can operate hundreds of hours with the IGBT on-die temperature of 200 °C, and the gate driver board chip of 127 °C. The findings in this study could help to the improvement design of the traction inverter, as well as to keep the design life prediction never be overestimated.
engineering, electrical & electronic,transportation science & technology
What problem does this paper attempt to address?
The problem this paper attempts to address is: evaluating the weak points of traction inverters under high-temperature stress and the performance of their various components, particularly the impact of high temperatures on traction inverters. Through the Highly Accelerated Life Testing (HALT) method, researchers aim to identify the weaknesses of traction inverters in harsh environments and improve their reliability. Specifically, the objectives of the paper include: 1. **Evaluating the reliability and performance of traction inverters under high-temperature conditions**: Conducting HALT tests within the high-temperature range of 190°C to 220°C to study the performance of traction inverters under extreme temperatures. 2. **Identifying the weak points of the system**: Observing changes in electrical and thermal indicators through online monitoring systems to identify components that are prone to failure under high-temperature conditions. 3. **Analyzing the impact of different conditions on test time and failure modes**: Investigating the effects of different temperature step stresses on overall test time, failure modes, and damage conditions through group testing. 4. **Improving design and life prediction**: Providing a basis for design improvements of traction inverters through experimental results to ensure that design life predictions are not overestimated. These studies are of great significance for improving the reliability and safety of electric vehicles (EVs) and hybrid electric vehicles (HEVs).