Influence of Revised Kinetics Model on DPF's Thermal Regeneration

唐君实,宋蔷,徐小波,李水清,姚强
2010-01-01
Abstract:Based on change of specific surface area of soot determined by TGA isothermal oxidation test and kinetic parameters of soot oxidation determined by temperature programmed oxidation test,an advanced model describing the thermal regeneration process in monolith was developed,in which a new formula of soot oxidation was incorporated.Numerical simulation of DPF regeneration process was developed to compare this advanced model with traditional B-K model.The comparison results showed that B-K model overestimated necessary regeneration time,and underestimated maximum wall temperature and maximum wall temperature gradient.The difference of numerical results by the two models was revealed by a soot oxidation equation.The advanced model is helpful for optimizing DPF regeneration process and in achieving economy and safety of the process.
What problem does this paper attempt to address?