An Analysis Of Saturated Critical Heat Flux In Micro/Mini-Channels

Zan Wu,Wei Li.,Zhike Wang
DOI: https://doi.org/10.1115/FEDSM-ICNMM2010-30603
2011-01-01
Abstract:This paper verified the macro-to-micro-scale transitional criterion BoRe(1)(0.5) = 200 proposed by Li and Wu [W. Li, Z. Wu, A general criterion for evaporative heat transfer in micro/mini-channels, International Journal of Heat and Mass Transfer 53 (2010) 1967-1976] because data points where BoRe(1)(0.5) <= 200 and BoRe(1)(0.5) > 200 show very different trends for the entire database (1,672 data points). For the 859 data points with BoRe(1)(0.5) <= 200, the boiling number at CHF decreases greatly with length-to-diameter ratio L-h/d(he) when L-h/d(he) is small, while L-h/d(he) presents negligible effect on the boiling number when L-h/d(he) > 150. For the region where L-h/d(he) <= 150 and BoRe(1)(0.5) <= 200, a simple saturated CHF correlation was proposed by using the boiling number, length-to-diameter ratio, and exit quality. Heated length and heated equivalent diameter were adopted in the length-to-diameter ratio, considering the actual heat transfer conditions. A combined dimensionless number We(m)Ca(1)(0.8) was introduced to correlate the micro/mini-channel database for the region: L-h/d(he) > 150 and BoRe(1)(0.5) <= 200. The new method can predict the overall micro/mini-channel database accurately on the whole. It can predict almost 95.5% of the non-aqueous data and 93.5% of the water data within the +/- 30% error band.
What problem does this paper attempt to address?