Effects of heat capacity of a Hot disk probe on thermal conductivity measurement

Qiang Wang,DAI Jing-min,HE Xiao-wa
2009-01-01
Abstract:The effects of the heat capacity of a hot disk probe on thermal conductivity measurement were investigated experimentally. The transient plane source technique is based on the transient heating of a double spiral plane sandwiched between two pieces of the investigated material. Based on the ideal model of the transient plane source method, a model for correcting the effects of heat capacity on the real heating power was presented. Pyroceram 9606 material was measured and analyzed by using the developed model and the hot disk data acquisition system with different radius probes. The results indicate that the thermal conductivity measurement accuracy was improved by using the developed model, and the estimated relative error caused by the heat capacity of a hot disk probe was sensitive to different choices of test parameters. It is possible to conclude that the relative quantity between the probe heat capacity and the total quantity of heat is the decisive factor for different thermal conductivity measurement relative error.
What problem does this paper attempt to address?